GE Monogram Refrigerator Noisy Mullion
GE Monogram Refrigerator Noisy Mullion maybe loud and some may flip closed during door operation. Mullions may make noise against the bins when the left door is opened. Occasionally the mullion may also flip back to the closed position during door openings.
Models affected: ZIPS360NHA, ZIPP360NHA, ZIP360NHA
Solution: The two foam strips have been replaced with three rubber bumpers. Mullions with two foam strips should be replaced with WR17X26528. If the mullion is loose and flips back to the closed position (shown in the above pictures), one or two bushings (WR02X26692) should be added between the lower mullion hinge and the mullion to tighten the mullion. Note: When bushings are used, ensure the top of the mullion is not rubbing the top of the mullion striker. Should the mullion be rubbing remove a bushing.
GE Monogram Refrigerator Repair San Diego
Disclaimer: The Technical Reference Materials (hereinafter “Materials”) at this site are intended for viewing and use by qualified appliance service technicians. If you do not possess sufficient mechanical and electrical skills and the ability to comprehend, understand and follow all safety warnings and cautions on the product in these Materials, do not attempt to undertake the repairs that are depicted in these Materials. MD Appliance LLC disclaims any and all liability, to the fullest extent permitted by law, arising out of your use of the site and Materials.