Yearly Archives - 2018

GE Slide-in Gas Ranges oven shut down

Models affected: C2S986SEL1SS, C2S995SEL1SS, CGS986EEL1DS, CGS986SEL1SS, CGS995EEL1DS, CGS995SEL1SS, CHS985SEL1SS, CHS995SEL1SS, JGS760BEL1TS, JGS760DEL1BB, JGS760DEL1WW, JGS760EEL1ES, JGS760SEL1SS, P2S930SEL1SS, PGS930BEL1TS, PGS930EEL1ES, PGS930SEL1SS, PGS960BEL1TS, PGS960EEL1ES, PGS960SEL1SS Problem: Bake and Broil operations shut down when temperature reaches approximately 250F. If the selected bake or broil function operates for a short period of time and then shuts down, the problem is not with the ERC. A problem may exist with the cooling blower motor or the motor wiring. Repair Procedure:
  1. Enter the range ERC’s Fault Retrieval Mode to display the hidden fault codes (see unit’s Mini-Manual). Fault code F350 will likely be displayed. This indicates the ERC has detected the cooling fan blower wheel is not turning as fast as it should or is not turning at all.
  2. After cycling power to the range, enter the ERC’s Service (Test) Mode. Activate the cooling blower at low speed for a few seconds by pressing ‘3’.If the blower, which is visible through the vent trim at rear of maintop, fails to spin or spins very slowly, investigate the cause by removing the range maintop. Inspect the blower wheel for obstruction by wire routing, foreign objects or insulation pressing on the red silicone hub of the blower wheel and repair as needed. The blower wheel should rotate freely by hand without noise or undue friction.
  3. Verify wiring connections to the low speed (black wire) and high speed (red wire) tabs of the blower motor. Verify wiring connection to the Neutral (white wire) of the blower motor. Verify the gray plastic 6-pin connector is completely connected. If either of these checks fails the problem is in the wiring or connectors going to the blower motor.
  4. Reactivate the cooling blower in the Service Mode and check for 120 volts AC to the low speed tab (black wire) and the neutral tab (white wire) of the blower motor (see strip circuit below). Check for good connection and voltage at door lock motor switch and J903 pin 1 on RC17 machine board on rear of unit. If 120 volts is not present from J903 pin 1 to neutral when cooling fan is on in service mode, replace the machine board.
  5. Disconnect power and check for resistance between white to red (~ 31 ohms) and white to black (~ 47 ohms) on the blower motor. If all wiring checks are correct and the blower wheel rotates freely, replace the blower motor assembly (BLOWER TANGENTIAL - WB26X29060) by removing the four hex-head screws that attach the assembly to the blower shroud. The upper back wire cover and the right side panel will have to loosened to remove and replace the blower assembly.

Service Bulletin RA02-18

Disclaimer: The Technical Reference Materials (hereinafter “Materials”) at this site are intended for viewing and use by qualified appliance service technicians. If you do not possess sufficient mechanical and electrical skills and the ability to comprehend, understand and follow all safety warnings and cautions on the product in these Materials, do not attempt to undertake the repairs that are depicted in these Materials. MD Appliance LLC disclaims any and all liability, to the fullest extent permitted by law, arising out of your use of the site and Materials.

KitchenAid Built-in SxS Refrigerator too warm in the refrigeration compartment

Note: All KitchenAid Refrigerators K and M Models, Example model KSSC42FK Problem: Too warm in the refrigerator, or too warm in the top shelf area of the refrigerator compartment. Posible Cause: Not enough air is directed to the top right side of the upper shelf area on some refrigerators. Recommended Solution: The air diverter has been redesigned to direct more air to the top shelf area. Remove the cover and compare the air diverter to the old and new diverters pictured. Replace the old diverter with a new diverter #2309222.
MD Appliance LLC offers professional Kitchen Aid Refrigerator Repair San Diego CA. With many years of experience and over 15.000 customers served in last two decades we are one of the most trusted and best rated KitchenAid appliance repair company in San Diego and surrounding areas. Contact us if you need troubleshooting assistance or a service visit.
 

Disclaimer: The Technical Reference Materials (hereinafter “Materials”) at this site are intended for viewing and use by qualified appliance service technicians. If you do not possess sufficient mechanical and electrical skills and the ability to comprehend, understand and follow all safety warnings and cautions on the product in these Materials, do not attempt to undertake the repairs that are depicted in these Materials. MD Appliance LLC disclaims any and all liability, to the fullest extent permitted by law, arising out of your use of the site and Materials.

Miele Freezers Gurgling Noise

Problem: when closing the freezer door unit is making gurgling or hissing  sound, and the door locks itself for a short time. Possible Cause: frost buildup inside the door vent membrane, air vent blocked with food Solution: clean and replaced the door vent membrane and clear the space in front of the air vent.

Disclaimer: The Technical Reference Materials (hereinafter “Materials”) at this site are intended for viewing and use by qualified appliance service technicians. If you do not possess sufficient mechanical and electrical skills and the ability to comprehend, understand and follow all safety warnings and cautions on the product in these Materials, do not attempt to undertake the repairs that are depicted in these Materials. MD Appliance LLC disclaims any and all liability, to the fullest extent permitted by law, arising out of your use of the site and Materials.

 

Thermador Freezer Error E34

Appliance Behavior: ice maker stops making ice, shows error E34 on the display. Posible Cause: hopper flap switch error Recommended Solution: remove hopper and move hopper flap opening lever arm manually, check the lever arm whether it is stucked or not. If it is not, crusher lever motor mechanism might be faulty. Change the crusher.

Disclaimer: The Technical Reference Materials (hereinafter “Materials”) at this site are intended for viewing and use by qualified appliance service technicians. If you do not possess sufficient mechanical and electrical skills and the ability to comprehend, understand and follow all safety warnings and cautions on the product in these Materials, do not attempt to undertake the repairs that are depicted in these Materials. MD Appliance LLC disclaims any and all liability, to the fullest extent permitted by law, arising out of your use of the site and Materials.

Bosch Dishwasher Error E24

Dishwasher Behavior: Wash cycle completed prematurely,dishwasher won’t drain, Sanitized LED is lit and E:24  shows on display. Posible Couse: I found out that in most cases  clogged drain line, drain hose or back-flow will cause the dishwasher to slowly drain or not to drain water at all. Sometimes the drain pump malfunctions or gets plugged with food waste. Solution: Unclog house drain line, drain hoses & backflow valve or replace the drain pump.

Disclaimer: The Technical Reference Materials (hereinafter “Materials”) at this site are intended for viewing and use by qualified appliance service technicians. If you do not possess sufficient mechanical and electrical skills and the ability to comprehend, understand and follow all safety warnings and cautions on the product in these Materials, do not attempt to undertake the repairs that are depicted in these Materials. MD Appliance LLC disclaims any and all liability, to the fullest extent permitted by law, arising out of your use of the site and Materials.